Components
- Batteries
- Electronics
- Generators
- Installation
- Complete Systems
- Brands
Filter
–
Components
3 Results
Sorting
VAT-exempt delivery possible*
2-12-00M202
Kemo m202 lead battery activator / refresher 12 v
The Kemo m202 lead battery activator / refresher works against the deposition of lead sulfate and thus increases the service life of the car battery. By very violent, very short current pulses lead sulfate is actively reduced or the deposit is prevented. With led display. The lead battery activator can be permanently connected directly in parallel to the 12v car battery.Circuit descriptionSulfate forms on the plates of lead acid batteries, especially in batteries that are little used or only operated seasonally (e.g. motorcycles with winter break). During self-discharge during idle time, crystalline sulfates slowly cover the lead plates and lead to a reduction in the capacity of the lead-acid battery. The Lead-Acid Activator is simply connected in parallel with the battery and uses very short, very violent current pulses to reduce the sulfate deposits and allow existing sulfate deposits to slowly degrade. It does not matter whether the battery is being charged or not. A trickle charger can therefore be connected at the same time, e.g. in the case of Mottorad batteries. Of course, the lead battery activator also extends the life of car batteries that are in daily active operation.Technical dataOperating voltage: approx. >11-16VAutomatic deactivation: approx. <11vMax. Pulse current: approx. <100ADuration pulse current: approx. 100 µSekPulse sequence: approx. every 5 secCurrent consumption: ca. <0,2mAPulse display: ledCan also be used for GEL batteriesDimensions: approx. 74 x 51 x 30 mm (without mounting straps)Commissioning:If the lead battery activator has been connected to the battery and the battery has a voltage of at least 11v, then the built-in led flashes only briefly at intervals of about 5 sec. each time, signaling the operating status.Scope of delivery:1x Kemo m202 lead battery activator / refresher
The Kemo m202 lead battery activator / refresher works against the deposition of lead sulfate and thus increases the service life of the car battery. ...
Shipped in 1-3 days
Shipped in 1-3 days
VAT-exempt delivery possible*
The Kemo m202 lead battery activator / refresher works against the deposition of lead sulfate and thus increases the service life of the car battery. By very violent, very short current pulses lead sulfate is actively reduced or the deposit is prevented. With led display. The lead battery activator can be permanently connected directly in parallel to the 12v car battery.Circuit descriptionSulfate forms on the plates of lead acid batteries, especially in batteries that are little used or only operated seasonally (e.g. motorcycles with winter break). During self-discharge during idle time, crystalline sulfates slowly cover the lead plates and lead to a reduction in the capacity of the lead-acid battery. The Lead-Acid Activator is simply connected in parallel with the battery and uses very short, very violent current pulses to reduce the sulfate deposits and allow existing sulfate deposits to slowly degrade. It does not matter whether the battery is being charged or not. A trickle charger can therefore be connected at the same time, e.g. in the case of Mottorad batteries. Of course, the lead battery activator also extends the life of car batteries that are in daily active operation.Technical dataOperating voltage: approx. >11-16VAutomatic deactivation: approx. <11vMax. Pulse current: approx. <100ADuration pulse current: approx. 100 µSekPulse sequence: approx. every 5 secCurrent consumption: ca. <0,2mAPulse display: ledCan also be used for GEL batteriesDimensions: approx. 74 x 51 x 30 mm (without mounting straps)Commissioning:If the lead battery activator has been connected to the battery and the battery has a voltage of at least 11v, then the built-in led flashes only briefly at intervals of about 5 sec. each time, signaling the operating status.Scope of delivery:1x Kemo m202 lead battery activator / refresher
Shipped in 1-3 days
2-12-00M120
Kemo m120 infrared spotlight for ccd cameras
With the Kemo m120 infrared spotlight, objects are visible to ccd cameras even in complete darkness. For humans, the infrared light is invisible, ccd cameras can see well with an infrared spotlight. Ideal for more "inconspicuous" observation of house entrances, driveways, etc.Note on operationccd cameras have different sensitivity. Therefore, the range of the infrared spotlight may be different, depending on the sensitivity of the camera. This infrared spotlight should only be used in complete darkness, without extraneous light influence. Reason: many cameras have a light sensor that regulates the sensitivity of the camera depending on the brightness of the day. This light sensor responds preferentially to visible light. So if there is another, weak light source (candle, monitor screen or similar), the sensor will immediately regulate the camera's sensitivity back and you will have the impression that the spotlight has almost no effect.Technical dataOperating voltage: 12-15 v/dcPower consumption: <300mARange: approx. 5mWavelength: approx. 875 nmDimensions: approx. 72 x 50 x 18 mm (with LEDs)Commissioning:The infrared spotlight must be mounted in a weather-protected location. For operation either a rechargeable battery 12 v/dc or a stabilized power supply with an output voltage between 12-15 v/dc is suitable. The power supply must have an output of at least 300mA. The spotlight has its maximum power at an operating voltage between 12 and 15 v/dc. If the operating voltage is too low, the performance of the headlamp will drop significantly. If the operating voltage is too high (>15 v/dc), the unit will generate too much heat and may become defective.Scope of delivery:1x Kemo m120 infrared spotlight for ccd cameras
With the Kemo m120 infrared spotlight, objects are visible to ccd cameras even in complete darkness. For humans, the infrared light is invisible, ccd ...
Shipped in 1-3 days
Shipped in 1-3 days
2-12-00M120
Kemo m120 infrared spotlight for ccd cameras
With the Kemo m120 infrared spotlight, objects are visible to ccd cameras even in complete darkness. For humans, the infrared light is invisible, ccd cameras can see well with an infrared spotlight. Ideal for more "inconspicuous" observation of house entrances, driveways, etc.Note on operationccd cameras have different sensitivity. Therefore, the range of the infrared spotlight may be different, depending on the sensitivity of the camera. This infrared spotlight should only be used in complete darkness, without extraneous light influence. Reason: many cameras have a light sensor that regulates the sensitivity of the camera depending on the brightness of the day. This light sensor responds preferentially to visible light. So if there is another, weak light source (candle, monitor screen or similar), the sensor will immediately regulate the camera's sensitivity back and you will have the impression that the spotlight has almost no effect.Technical dataOperating voltage: 12-15 v/dcPower consumption: <300mARange: approx. 5mWavelength: approx. 875 nmDimensions: approx. 72 x 50 x 18 mm (with LEDs)Commissioning:The infrared spotlight must be mounted in a weather-protected location. For operation either a rechargeable battery 12 v/dc or a stabilized power supply with an output voltage between 12-15 v/dc is suitable. The power supply must have an output of at least 300mA. The spotlight has its maximum power at an operating voltage between 12 and 15 v/dc. If the operating voltage is too low, the performance of the headlamp will drop significantly. If the operating voltage is too high (>15 v/dc), the unit will generate too much heat and may become defective.Scope of delivery:1x Kemo m120 infrared spotlight for ccd cameras
Shipped in 1-3 days
2-12-00M104
Kemo 4 Kanal Computer Schalter M104
Converts a battery voltage of 9 - 12V DC into a weak pulsing high voltage of about 1000V.
For small animal fences, as burglary protection, etc. To release an electrical stroke both high voltage wires have to be touched by the animals paw, tounge, snout or alike at the same time
Converts a battery voltage of 9 - 12V DC into a weak pulsing high voltage of about 1000V.
For small animal fences, as burglary protection, etc. To re...
Shipped in 1-3 days
Shipped in 1-3 days
2-12-00M104
Kemo 4 Kanal Computer Schalter M104
Converts a battery voltage of 9 - 12V DC into a weak pulsing high voltage of about 1000V.
For small animal fences, as burglary protection, etc. To release an electrical stroke both high voltage wires have to be touched by the animals paw, tounge, snout or alike at the same time
Shipped in 1-3 days