Flat cable ÖLFLEX H1Z2Z2-K 1x10mm² WH/BK solar cable sold by the meter
Shipped in 1-3 days
€2.24*
€1.88**
Lapp ÖLFLEX SOLAR H1Z2Z2-K cables are weather-, abrasion- and UV-resistant photovoltaic cables. These halogen-free, double-insulated and cross-linked solar cables are suitable for permanent outdoor use to connect grounded and ungrounded photovoltaic systems. They are used both for cabling solar modules to each other and for connecting the individual module rows and the inverter. The cable has been type-tested by TÜV Rheinland in accordance with 2 PfG 1169/08.2007 (PV1-F).
This item is sold by the meter. Each item corresponds to one meter. For example, if you purchase 10 of these items, you will receive one continuous piece with a length of 10 m.
Important product features:
Conductor cross-section: 10mm²
Manufacturer: Lapp Kabel
Outer insulation color: Black
ÖLFLEX H1Z2Z2 solar cables from Lapp can generally be laid in protective conduits suitable for underground installation, provided that there is no permanent contact with water and that any accumulated water is safely drained away. The laying of cables in the ground and the correct execution of the cable trench must comply with VDE 0100 Part 520 or comparable standards in order to prevent damage to the protective conduit and permanent exposure of the cables and wires to penetrating water. Long-term, permanent storage and continuous operation of the cables in or under water is not permitted.
Conductor structure
1. Conductor: Fine-stranded stranded wire made of tinned copper wires, in accordance with IEC 60228, class 5
2. Core insulation: Electron beam cross-linked polyolefin copolymer
3. Outer sheath Electron beam cross-linked polyolefin copolymer
Electrical properties
Nominal voltage: U0 /U according to IEC AC 1000/1000 V - DC 1500/1500 V
Max. permissible system voltage: 1.8 kV DC (conductor/conductor, ungrounded system) according to TÜV 2 PfG 1169/08.2007 Test voltage AC 6.5 kV - DC 15 kV
Thermal properties
Temperature range fixed: -40°C to +120°C Max. conductor temperature (according to EN 60216-2)
Temperature range for fixed installation: -40°C to +90°C Ambient temperature (according to TÜV 2 PfG 1169/08.2007)
Flexible installation temperature: max. -25 °C
Heat resistance according to EN 60811-3-1
Moisture and heat test according to EN 60068-2-78 at 85% humidity
Mechanical properties
Minimum bending radius when occasionally moved: 4x outer diameter
Minimum bending radius when fixed: 5 x cable diameter
Dynamic penetration according to DKE requirement profile PV1-F AK 411.2.3 Appendix F
Tear resistance according to DKE requirement profile PV1-F AK 411.2.3 Appendix G
Tensile strength and elongation test according to EN 60811
Chemical properties
Weathering/UV resistance according to EN 50618
Ozone resistance according to EN 50396, method B
Halogen-free in accordance with EN 50267, EN 50525-1
Fire behavior flame retardant according to IEC 60332-1-2
Acid and alkali resistance according to EN 60811-404 (oxalic acid and caustic soda)
Scope of delivery
1x 1m Lapp ÖLFLEX solar cable H1Z2Z2-K 1X10 WH/BK
Manufactuerer Information
Lapp
U.I. Lapp GmbH
Schulze-Delitzsch-Straße 25
70565 Stuttgart
Germany
Mail: info.de.uil@lapp.com
Tel.: +49 711 783801