Safe shopping with solar experts
Fast Shipping
Top choice renowned brands
Customer service:
+49 (0) 8721 91994-00

Lapp SOLAR XLR-R cables are weather-, abrasion-, and UV-resistant photovoltaic cables. These halogen-free, double-insulated, and cross-linked solar cables are suitable for permanent outdoor use to connect grounded and ungrounded photovoltaic systems. They are used both for cabling solar modules to each other and for connecting the individual module rows and the inverter. The cable has been type-tested by TÜV Rheinland in accordance with 2 PfG 1169/08.2007 (PV1-F).

Important product features:

Cable cross-section: 1x4mm
Manufacturer: Lapp Kabel
Outer insulation color: Black
Inner insulation color: White

XLR-R solar cables from Lapp can generally be laid in protective conduits suitable for underground installation, provided that there is no permanent contact with water and that any accumulated water is safely drained away. The laying of cables in the ground and the correct execution of the cable trench must comply with VDE 0100 Part 520 or comparable standards in order to prevent damage to the protective conduit and permanent exposure of the cables and wires to penetrating water. Long-term, permanent storage and continuous operation of the cables in or under water is not permitted.

Conductor structure

1. Conductor: Fine-stranded stranded wire made of tinned copper wires, in accordance with IEC 60228, Class 5
2. Conductor insulation: Electron beam cross-linked polyolefin copolymer
3. Outer sheath Electron beam cross-linked polyolefin copolymer Outer sheath color: black or black with red or blue stripes

Electrical properties

Nominal voltage: U0 /U according to IEC AC 600/1000 V DC 900/1500 V
Max. permissible system voltage: 1.8 kV DC (conductor/conductor, ungrounded system) according to TÜV 2 PfG 1169/08.2007 Test voltage AC 6.5 kV

Thermal properties

Temperature range for fixed installation: -40°C to +120°C Max. conductor temperature (according to EN 60216-2)
Temperature range for fixed installation: -40 °C to +90 °C Ambient temperature TUV 2 PfG 1169/08.2007
Flexible installation temperature: max. -25 °C
Heat pressure resistance according to EN 60811-3-1
Moisture and heat test according to EN 60068-2-78 at 85% humidity

Mechanical properties

Minimum bending radius occasionally moved: 15 x cable diameter
fixed installation: 5 x cable diameter
Dynamic penetration according to DKE requirement profile PV1-F AK 411.2.3 Appendix F
Tear resistance according to DKE requirement profile PV1-F AK 411.2.3 Appendix G
Testing of tensile strength and elongation according to EN 60811

Chemical properties

Weathering/UV resistance according to HD 605/A1
Ozone resistance in accordance with EN 50396
Halogen-free in accordance with EN 50267
Fire behavior flame retardant according to IEC 60332-1-2
Acid and alkali resistance according to EN 60811-2-1 (oxalic acid and caustic soda)

Manufacturer: Lappkabel

Manufactuerer Information

Lapp

U.I. Lapp GmbH
Schulze-Delitzsch-Straße 25
70565 Stuttgart
Germany

Mail: info.de.uil@lapp.com

Tel.: +49 711 783801

offgridtec.com Reviews with ekomi.de
Loading products