BMV 700 Battery Monitor

Precise Monitoring
The primary function of battery monitoring is to record the amp-hours consumed and the current state of charge of the battery. The ampere-hours are determined by integrating the current flowing into or out of the battery. At a constant current, integration corresponds to the multiplication of current and time. For example, a discharge current of 10A over 2 hours yields a value of 20Ah. Victron battery monitors are equipped with powerful microprocessors programmed for specific tasks.

Battery "fuel gauge," remaining capacity indicator, and much more
The remaining battery capacity depends on the amp-hours consumed, the discharge current, the
temperature, and the age of the battery. Complex software algorithms are required to account for all these
variables.
In addition to basic display options such as voltage, current, and consumed
amp-hours, the BMV-700 series also displays the state of charge, remaining runtime, and power consumption in
watts.

Easy Installation
All electrical connections are made to the current shunt via the PCB connector
. The shunt is connected to the monitor via a standard RJ12 telephone cable.
Scope of delivery includes: RJ12 cable (10 m) and battery cable with fuse (2 m); no additional
components required.

Also included are a separate front bezel for a square or round display; a safety ring
for rear mounting, and screws for front mounting.

Easy Programming
A quick installation menu and a detailed setup menu with scrolling assist the user when
configuring the various settings. Please refer to the manual for further details.

Standard functions
- Battery voltage, current, power, amp-hours consumed, and state of charge
- Remaining runtime at current discharge rate
- Programmable visual and audible alarm
- Programmable relay to shut off non-essential loads or start a generator
.
- A 500-amp quick-connect shunt and a connection kit.
- Shunt capacity selectable up to 10,000 amps.
- VE.Direct communication port
- Stores a wide range of historical data that can be used to analyze usage patterns and battery condition
.
- Wide input voltage range: 9.5–95 V
- High current measurement resolution: 10 mA (0.01 A)
- Low power consumption: 2.9 Ah per month (4 mA) at 12 V and 2.2 Ah per month (3 mA) at 24 V
No additional components are required.
- Extremely simple installation: Separate front panels (square or round), ring for rear mounting or screws for front mounting.

Resolution and accuracy(with a 500 A shunt)
Current ± 0.01 A
Voltage ± 0.01 V
Ampere-hours ± 0.1 Ah
State of charge (0–100%) ± 0.1%
Remaining runtime ± 1 min
Current measurement accuracy ± 0.4%
Voltage measurement accuracy ± 0.3%
Standards
Safety EN 60335-1
Emissions / Immunity EN 55014-1 / EN 55014-2
Automotive Industry ECE R10-4 / EN 50498
Accessories
Shunt (included) 500 A/50 mV

Category name: Accessories battery
Manufacturer: Victron Energy
Operating temperature range: -40°C - +50°C
Power consumption: < 4 mA
ean: 8719076020073
mpn: BAM010700000R

Manufactuerer Information

Victron Energy

Victron Energy B.V.
De Paal 35
1351 JG Almere
Netherlands

Mail: sales@victronenergy.com

Tel.: +31 365359700

Direkt zum Hersteller

Victron_BMV-7xx_Dimensions.pdf Download
Victron_BMV_CE.pdf Download
Victron_BMV_Automatic-Generator.pdf Download
Loading products