Skip to main content Skip to search Skip to main navigation
Safe shopping with solar experts
Fast Shipping
Top choice renowned brands
Customer service:
+49 (0) 8721 91994-00

Similar Products

VAT-exempt delivery possible*
Blau-graues Victron Energy Multi HS19 Solar 15k Gerät mit roten und schwarzen Schaltern sowie grünem Anschlussblock - Ansicht von links
1-67-025157
Victron Multi HS19 Solar 15 kW System Combination
€5,057.50* €4,250.00**

The Multi HS19 unit from Victron Energy (MPN: PMR803150300) has a rated power of 15 kW and was designed for 650–1000 V systems. It combines 3-phase po...

Shipped in 2-5 Days (Mo-Fri)

Shipped in 2-5 Days (Mo-Fri)

VAT-exempt delivery possible* Preorder 26.11.2026
Victron MultiPlus 24/1200/25-16 230V
1-67-011815
Victron MultiPlus 24/1200/25-16 230V
€499.68* €419.90**

The new MultiPlus 24/1200/25-16 (Victron Energy, PMP242120000) is the successor to the Multiplus Compact 24/1200. This device is a modern combination ...

Product is expected to be back in stock on 26 November 2026

Product is expected to be back in stock on 26 November 2026

VAT-exempt delivery possible* Preorder 25.11.2026
Victron MultiPlus C 12/800/35-16 12V 230V 700W 1400W inverter 35A charger
1-67-009005
Victron MultiPlus C 12/800/35-16 12V 230V 700W 1400W inverter 35A charger
€508.78* €427.55**

The Multiplus C 12/1200/35 from Victron (MPN CMP121800000) is a combination device consisting of a 12V 700W sine wave inverter and battery charger. Th...

Product is expected to be back in stock on 25 November 2026

Product is expected to be back in stock on 25 November 2026

VAT-exempt delivery possible*
Victron MultiPlus 48/3000/35-50 48V 230V 2400W 6000W inverter 35A charger
1-67-009065
Victron MultiPlus 48/3000/35-50 48V 230V 2400W 6000W inverter 35A charger
€924.51* €776.90**

The Multiplus 48/3000/35-50 from Victron (MPN PMP243021011) is a combination device consisting of a 48V 2400W sine wave inverter and battery charger. ...

Shipped in 10-14 Werktage (Mo-Fr)

Shipped in 10-14 Werktage (Mo-Fr)

Matching Products

Victron GlobalLink 520 4G LTE-M System Monitoring
8-67-013440
Victron GlobalLink 520 4G LTE-M System Monitoring
€233.66*

The GlobalLink 520 from Victron Energy (MPN ASS030543020) provides insight into your installation and is a crucial factor in the maintenance and opera...

Shipped in 1-3 Days (Mo-Fri)

Shipped in 1-3 Days (Mo-Fri)

VAT-exempt delivery possible*
Victron vm-3p75ct Energy Meter compteur électrique triphasé 75A/phase
8-67-018530
Victron VM-3P75CT Energy Meter 3-phase electricity meter incl. 75A current transformer
€185.10* €155.55**

The Victron Energy VM-3P75CT (MPN REL200300100) is a 3-phase electricity meter with three current transformers (CTs) included for up to 75 A per phase...

Shipped in 1-3 Days (Mo-Fri)

Shipped in 1-3 Days (Mo-Fri)

The Victron Multi RS19 Solar 48/6000/100-450/100 (MPN: PMN482602000) combines an inverter, battery charger, 50 A transfer switch, and two MPPT solar charge controllers in a single 19-inch rack-mount unit. This combination unit is designed for stationary 48 V systems with a battery, photovoltaic array, and optional utility grid or generator connection. Hybrid, standby, off-grid, and generator modes enable integration into various power supply configurations.

Key features of the Multi RS19 Solar

  • Continuous inverter power output ranging from 4,800 W at 46 V to 5,300 W at 52 V and 25 °C
  • 9 kW peak power for 3 seconds and 7 kW for 4 minutes
  • Two independent MPPT trackers with a total DC solar charging capacity of 6 kW
  • PowerControl and PowerAssist for limiting and supplementing the available AC input power
  • Integrated display, Bluetooth, and configuration via VictronConnect
  • VE.Direct, VE.Can, and BMS-Can for system communication
  • Single-phase or three-phase operation with one unit per phase

Two separate MPPT trackers for the solar system

The two independent MPPT trackers each handle up to 3 kW, for a combined maximum of 6 kW DC solar charging power. Each tracker has its own PV string connection with MC4 connectors. Separate trackers facilitate the integration of module arrays with different orientations or that are subject to varying levels of shading at different times. The controller continuously adjusts the operating point of the connected solar modules so that the available PV power can be utilized under the respective irradiance and temperature conditions. The device’s maximum PV open-circuit voltage is 450 V. Additionally, the PV voltage must not exceed eight times the set battery float charge voltage. For example, with a battery voltage of 50 V, this results in a system-specific limit of 400 V. Both conditions must be taken into account when designing the string configuration.

Charging from PV and AC Sources

The battery can be charged via the two integrated MPPT trackers as well as via a connected AC source. Under the defined rated conditions, the maximum charging current from the AC input is 88 A. The combined charging current from AC and PV is limited to 100 A. The three-stage charging process consists of constant-current, constant-voltage, and trickle-charging phases. Charging voltages and other parameters can be configured to match the battery system in use. For regulated lithium batteries, communication with the respective BMS must be technically approved and correctly configured.

Hybrid, Standby, Off-Grid, and Generator Operation

In hybrid mode , excess PV energy can be stored in a battery and made available again when power demand increases. In backup mode, the system supplies suitable loads via the battery and inverter in the event of an AC source failure. Off-grid operation is possible, as is combination with a generator. The unit can also be operated without a battery as an AC-coupled PV inverter. The battery, backup, and charging functions are not available in this operating mode. Full ESS functionality is not supported for all grid codes and installations. Suitability for grid-connected storage systems must therefore be verified based on the intended location and current Victron system approvals.

Configuration and System Communication

Operating data for the battery, inverter, and solar charging can be viewed on the integrated display or via Bluetooth in the VictronConnect app. VictronConnect can also be used to adjust the approved device and charging parameters. VE.Can is available for connection to a GX device. VE.Direct can be used, for example, with a GlobalLink 520 or, with the appropriate accessories, for access via a Windows computer. The BMS-Can connection supports regulated batteries with the appropriate CAN bus BMS-LV protocol. Special connection requirements apply to systems with a GX device or multiple devices. The sizing of the battery, DC cabling, fuses, and PV strings must be tailored to the possible charging, discharging, and short-circuit currents. Installation, configuration, and commissioning must be performed by appropriately qualified technical personnel.

Technical Specifications

  • Transfer switch: 50 A
  • Maximum AC input and through-current: 50 A
  • DC input voltage range: 38 to 62 V
  • Minimum turn-on voltage: 41 V
  • Overvoltage shutdown: 65.5 V
  • AC output: 230 V AC ± 2%
  • Output frequency: 50 Hz ± 0.1%
  • Maximum continuous inverter current: 25 A AC
  • Short-circuit output current: 45 A
  • Maximum overcurrent protection at AC output: 30 A
  • Efficiency: 96.5% at 1 kW load; 94% at 5 kW load
  • Power consumption without load: 20 W
  • Number of MPPT trackers: 2
  • Maximum PV conversion power: 6 kW total; 3 kW per tracker
  • Maximum PV open-circuit voltage: 450 V
  • PV start-up voltage: 120 V
  • MPPT operating voltage range: 65 to 450 V
  • Maximum operating PV input current limit: 12 A
  • Maximum PV short-circuit current: 16 A
  • AC input voltage range: 187 to 265 V AC
  • Programmable charging voltage range: 36 to 60 V
  • Maximum AC charging current: 88 A at 57.6 V under rated conditions
  • Maximum combined charging current from AC and PV: 100 A
  • Operating temperature: −40 to +65 °C
  • Maximum relative humidity: 95%, non-condensing
  • Protection rating: IP20
  • Weight: 12.2 kg
  • Dimensions: 133 × 483 × 430 mm

Package contents:

1x Victron Multi RS19 Solar 48/6000/100-450/100
1x Battery Temperature Sensor

Breite (mm): 430
Frequency range: 45 - 60 Hz
Humidity: max. 95% (non-condensing)
Höhe (mm): 133
Input voltage range AC: 187 - 265 VAC
Input voltage range DC: 38 - 62 VDC
Länge (mm): 483
MPPT-Anzahl: 2
MPPT-Spannungsbereich: 65 – 450 V
Manufacturer: Victron Energy
Nennspannung: 230V AC
Operating temperature range: -40°C - +65°C
Output voltage: 230V AC
Peak performance: 9 kW/3s und 7 kW/4min
Protection type: IP20
Weight: 12,2 kg
max. input current: 12 A pro Tracker
ean: 8719076058403
mpn: PMR482602030

Manufactuerer Information

Victron Energy

Victron Energy B.V.
De Paal 35
1351 JG Almere
Netherlands

Mail: sales@victronenergy.com

Tel.: +31 365359700

Direkt zum Hersteller

Victron_Multi-RS19-Solar_Konformitätserklärung.pdf Download
Victron_Multi-RS19-Solar_User-Manual.pdf Download
Victron_Multi-RS19-Solar_Datenblatt.pdf Download
1-67-025156
Loading products