Growatt SPA 7000TL3 BH-UP 7kW grid-connected inverter, 3-phase
Shipped in 1-3 days
€1,654.65*
€1,390.46**
The SPA 7000TL3 BH-UP from Growatt is a three-phase grid-connected inverter that provides a state-of-the-art solution for your solar projects. With three programmable operating modes, a VPP interface, and a wide battery voltage range of 100-550V, it offers efficiency and flexibility. In addition, retrofits and new systems are supported, and compatibility with high-voltage batteries is ensured.
about the SPA 7000TL3 BH-UP inverter
- 100% three-phase unbalanced output
- Intelligent power control at phase level
- Intelligent load control via dry contact
- Wide battery voltage 100-550 V
- UPS function, 10 ms transfer
- VPP interface
- Programmable operating modes
- Display via LED and LCD
- Easy installation
Intelligent load management
The integrated smart load control of the inverter enables precise and efficient control of energy consumption. The use of a potential-free contact allows electrical consumers to be controlled intelligently and prioritized. This function enables automatic detection of energy requirements and optimal use of the available energy. Smart load management ensures optimal energy distribution and thus contributes to efficient use. With intelligent load control via the dry contact, the inverter is able to optimize the energy flow and ensure efficient operation of your solar system.
Growatt monitoring platform
By using the optional accessories from the Shine series, you can use the Growatt monitoring platform. This platform is available as a smartphone app for iOS and Android as well as in a web version. The Shine accessories must be purchased separately, but use of the platform is free of charge. Shine allows you to configure and monitor all your Growatt products, and also enables you to view your self-consumption and track trends.
The following Shine options are compatible with the SPA series:
- ShineWiFi-X
- ShineLink-X
- Shine4G-X
- ShineMaster
Operating modes – Configurable depending on system requirements
Online mode
In online mode, users can set a suitable priority mode according to the request while the SPA is operating. When using the LCD and key settings, only one time period can be set. However, if the website settings are used, up to three time periods can be set for the priority mode
- Load First: With an inverter in the SPA system, the energy from the inverter is optimally used for the load and then the battery is charged. excess energy is exported to the grid. Without an inverter or if its energy is weak, the battery discharges first for the load and the grid supplies the energy when the battery capacity is insufficient.
- Battery First: When the SPA series operates in this mode, the battery is charged first. This is suitable for periods of low power consumption. The mode's switch-on and switch-off times and the end time of the battery charge status must be set. It is also possible to set a power output that is lower than the maximum output power of the battery. With an inverter in the SPA system, the energy from the inverter is used first for the battery and then for the load. The grid supplies the energy if the power output of the inverter is insufficient. Without an inverter, or if its energy output is too low, the battery and the load are supplied by the grid.
- Grid First: When the SPA series operates in Grid First mode, the energy is first fed into the grid. Time periods can be set when power consumption is too high. Here, the switch-on and switch-off times for the mode and the end time for the battery charge status must be specified. A power output can be set that is lower than the maximum output power of the battery. With an inverter in the SPA system, the battery discharges to the load. If the sum of the inverter power and battery power is greater than the load, excess energy flows into the grid. Without an inverter, or if its power is too weak, the battery discharges to the load and excess energy flows into the grid.
Backup mode:
If the grid fails, the system switches to backup mode and AC output is provided via the EPS LOAD connection using all the energy from the battery. Please note that the maximum output power of the SPA in this mode is 10,000W and the load connected to the EPS LOAD connection should be less than 10,000W. Note: You can only set one time period for "Battery First" and "Grid First" on the LCD. If you want to set more, do so via the Shineserver.
Error mode:
The SPA's intelligent control system continuously monitors and adjusts the status of the system. If the inverter detects unexpected events such as system errors or machine errors, the LCD display will show the error information and the LED light will illuminate in error mode.
Programming mode:
Programming mode indicates that the SPA system is being updated. The power supply should not be interrupted during this process. The inverter will automatically log out when the update is complete and switch to another mode.
check mode:
Before the SPA operates in normal mode, it will switch to self-check mode. If everything is OK, the system will switch to normal mode. Otherwise, the error mode will respond.
Standby mode:
If the system has no errors but the conditions are not met, the SPA remains in standby mode.
Technical data
- AC rated power: 7000W
- AC rated voltage range: 230/400V (310-476V)
- Frequency range: 50/60Hz, ±5Hz
- Max. output current: 10.6A
- Battery voltage range: 100-550V
- Max. charging and discharging current: 25A
- IP protection class: IP65
- Operating temperature range: -25°C to +60°C
- Maximum efficiency of 98.2%
- Dimensions: 505 x 453 x 198 mm
- Weight: 28 kg
Scope of delivery
1x Growatt SPA 7000TL3 BH-UP grid-connected inverter
Note on Growatt inverters when used with batteries
Please note that MIN, MOD, SPH, and SPA series inverters may only be operated with original Growatt batteries. All Growatt inverters sold in Europe are not compatible with lead-acid batteries. Using them may result in malfunctions or damage to the devices.
Manufactuerer Information
Growatt
Growatt New Energy B. V.
Klaverbaan 3
2908 KD Capelle aan den Ijssel
Netherlands
Mail: info@ginverter.com
Tel.: +31 850409967