Victron Skylla-TG 24/100(1+1) 230V 100A Battery Charger
€1,345.30*
The Victron Skylla-TG 24/100(1+1) 230V (MPN: SDTG2401001) is a stationary battery charger for high-capacity 24 V battery systems with a charging current of up to 100 A. The main output is supplemented by a separate 4 A output for a starter battery. The microprocessor-controlled IUoUo charging profile, temperature compensation, and voltage sensing allow for controlled adjustment of the charging voltage to suit the battery and installation. With a recommended battery capacity of 500 to 1,000 Ah, the unit is designed for appropriately sized battery systems.
100 A charging current for high-performance 24 V battery systems
- Up to 100 A charging current for the main battery
- Additional 4-A output for a starter battery
- Recommended battery capacity of 500 to 1,000 Ah
- Microprocessor-controlled IUoUo charging profile
- Temperature compensation via external temperature sensor
- Voltage Sense to compensate for line losses
- Adjustable charging parameters for different battery requirements
- Can also be used as a stabilized power source
- Dry contact alarm for external signaling
100 A charging current for large battery banks
With a maximum output current of 100 A, the unit is designed for larger 24 V battery banks. A battery capacity between 500 and 1000 Ah is recommended for this model. This version is therefore particularly suited for applications in which large energy storage systems are to be charged via a stationary 230 V mains supply. The charger has a maximum output power of 3,000 W and a maximum short-circuit current of 110 A. The rated power requires a properly sized AC and DC installation.
Three-stage IUoUo charging characteristic
The charging process is controlled via a microprocessor-controlled IUoUo characteristic curve. Initially, the unit charges the battery with high current during the boost phase. Once the specified battery voltage is reached, a phase with constant charging voltage follows. Subsequently, the unit switches to the lower float voltage. For the 24 V version, the standard specifications are 28.5 V boost/absorption voltage and 26.5 V float voltage.
Separate Output for the Starter Battery
The designation (1+1) refers to the combination of a main charging output and an additional output for a starter battery. While the main output provides up to 100 A, the separate starter battery output is limited to 4 A. This allows a separate starter battery to be charged or maintained at its state of charge simultaneously with a large consumer battery.
Temperature compensation accounts for battery temperature
The appropriate charging voltage for a battery varies with its temperature. The Skylla-TG therefore supports an external temperature sensor that is mounted directly on the battery. If the battery temperature rises, the charger reduces the charging voltage accordingly. When temperatures drop, the voltage can be adjusted. This is particularly relevant for sealed and maintenance-free batteries, as a charging voltage that is consistently too high can lead to overcharging and drying out.
Voltage Sense for More Precise Battery Voltage
At a 100 A charging current, even small resistances in long or poorly sized cables can cause a significant voltage drop. The Voltage Sense function therefore enables a separate voltage measurement directly at the battery terminals. The charger takes the measured voltage difference into account and can adjust its output voltage accordingly. This allows for the compensation of line losses of up to 2 V.
Adjustable Charging Parameters and Additional Operating Modes
In addition to the standard three-stage charging mode, various configuration options are available. The boost and float voltages, the equalization charging time setting, continuous boost charging, and compensation options for diode distributors and automotive battery applications can also be adjusted. The unit can also be used as a stabilized DC power supply, enabling operation even without a directly connected battery.
Integrated Protection Functions
The Skylla-TG features various protective mechanisms for operation. These include short-circuit protection, protection against excessive battery voltage, and temperature monitoring. If the internal temperature rises, the device initially reduces its output current. Under extreme thermal conditions, it shuts down and resumes operation once it has cooled sufficiently. The starter battery output also has a separate fuse.
Technical Specifications
- Battery system: 24 V
- Nominal input voltage: 230 V AC
- Input voltage range: 185–264/265 V AC
- Frequency: 45–65 Hz
- Maximum input current: 16 A at 230 V / 100 A
- Power factor: 1
- Main battery charging current: 100 A
- Charging current for starter battery: 4 A
- Recommended battery capacity: 500–1000 Ah
- Max. output power: 3,000 W
- Max. output current: 100 A
- Max. short-circuit current: 110 A
- Cooling: forced cooling
- Protection rating: IP21
- Ambient temperature: -40 to +50 °C
- Relative humidity: max. 95%
- Housing material: aluminum
- Battery connection: M8 bolt
- AC connection: Screw terminal
- Weight: 10 kg
- Dimensions: 365 × 250 × 257 mm
Package Contents
1x Victron Energy Skylla-TG 24/100(1+1) 230V battery charger
1x temperature sensor
Manufactuerer Information
Victron Energy
Victron Energy B.V.
De Paal 35
1351 JG Almere
Netherlands
Mail: sales@victronenergy.com
Tel.: +31 365359700